Strutconfigurator
System · data cables to length

Data cables to length, in the same bill of materials as the route

The support system and the cables inside it are usually ordered separately. Strutconfigurator brings them together: you choose the cables per containment run, the configurator calculates the fill and assembles the cables to length.

Short answer

With data cables to length alongside the route, you choose which cables go into the containment in the same configuration: Cat6A, fibre (OM4, OS2, MPO trunks) and power. The configurator calculates the fill ratio, checks power and data segregation and adds the cables to length, with connectors and labels, to the bill of materials.

Data cables to length, in the same bill of materials as the route600100Dividerdata | powerCat6A S/FTP × 80Ø 8.0 mmOM4 · MPO-12to length, labelledFILL 36% · LIMITS 40 / 60%Section600×100Cables154
data cables to lengthOwn drawing · to scale
  • Hosting Data stored in the EU · Frankfurt Stored with Neon (eu-central-1) · runs on the Cloudflare network
  • Privacy GDPR Data processing agreement available
  • System Brand-independent Public version · client version on your own range
  • Built by Built by NEXTRIQ 5.0 on Google · 22 reviews

Why cables and route in one enquiry?

Because the lengths come from the route. Whoever configures the containment knows how long each cable must be, how many fit in each tier and where they branch off. Doing it in one go avoids cables that are too short, trays that are too full and two suppliers waiting on each other. In our research of 19 November 2026, ChatGPT and Perplexity could not name a supplier that delivers both in one order.

Which cables can you choose?

The configurator uses the diameters of common types to calculate the fill ratio per run.

Cable types and diameters
CableUseDiameter (mm)
Cat6A U/FTPcopper, 10 Gbit/s7.5
Cat6A S/FTPcopper, screened8.0
OM4 patchmultimode fibre2.0
OM4 trunk MPO-12fibre, pre-terminated6.0
OS2 trunk MPO-12singlemode fibre6.0
3G2.5power10.5
5G6power16.0
5G16power22.0

Diameters are typical values (indicative); the cable manufacturer gives the exact size.

How does cable assembly work in the configurator?

Per line you choose the cable type, length, quantity and the connectors at both ends, with an optional label. Each line becomes one bill of materials line, so the supplier knows exactly what to make. Power and data in one run without a divider show a red status: the enquiry still goes through, with a clear warning.

  • Cable type, length in metres and quantity
  • Connector A and connector B, for example RJ45 or MPO
  • Label per cable or bundle
  • Fill ratio per run: up to 40% fine, up to 60% full, above that over-filled (rule of thumb)

Frequently asked questions

Can Cat6A and fibre share the same containment?

Yes, fibre is immune to interference. Protect fibre from kinking and crushing by heavy cables, for example with its own tier or raceway.

Do power and data need to be segregated?

Yes, with a divider or in separate containment, following the applicable IEC and national standards. The configurator warns when they are not.

What is an MPO trunk?

A pre-terminated fibre cable with MPO connectors, for example 12 fibres, laid quickly between racks in data centres.

Next step

See your own range in 3D.

In 30 minutes we show how your installers configure, what arrives on your side and what the client version on your range involves.

Manufacturer or wholesaler

Book a demo with Ismail

You see the configurator in your own brand and we discuss your range, systems and markets.

Reply from Ismail within one working day

Installer

Configure for free

A trapeze, frame or tray with cables in a few minutes, with a bill of materials and drawing.

Enquiry goes to a supplier · reply within one working day